Fire and life safety strategy report
What this document does
- Occupancy, means of escape, compartmentation, fire systems and smoke control set out against the UAE Fire and Life Safety Code for the civil defence submission.
- Sent by the Design Consultant to the Employer.
- Written to UAE practice.
What you get
- Report template with sections
- Checklist of attachments
- One-page guide on when and how to use it
- A full Arabic copy of every file, right to left
- File: Word, 11 pages
- Language: English, plus a full Arabic copy
- Brand-ready: your logo and company details go in when you download
- Pay once and use it on every project
Save with a pack
How to write a fire and life safety strategy
The fire and life safety strategy sets out how a building keeps people safe in a fire: how they get out, how fire and smoke are contained, and which systems detect and fight it. In the UAE it is written against the UAE Fire and Life Safety Code of Practice and agreed with the civil defence authority before the layouts are fixed.
What to include
- 1The basis: the code, the authority, the building use and its height
- 2The occupancy classification and the occupant load of each space
- 3Means of escape: exits, exit widths, travel distances and refuge areas
- 4Compartments, and the fire resistance of walls, floors and doors
- 5Fire systems: detection and alarm, sprinklers, hydrants, smoke control and emergency lighting
- 6How the systems work together: the cause and effect matrix
- 7Any departure from the code, with how the same level of safety is reached
When to use it
At schematic design, to agree the strategy with civil defence before the layouts are fixed. Update it for the detailed design submission, and again if the use or the layout changes.
The building is a 9-storey office block over 2 basement levels. Each floor has two protected stairs, and travel distances stay within the code’s limit for sprinklered offices. The building is fully sprinklered, with an addressable fire alarm, smoke extraction in the basements and pressurised stairs.
Common mistakes
- Using the occupant load of the wrong use, which makes the exits too narrow
- Specifying facade materials without test certificates that meet the code
- A cause and effect matrix that no longer matches the MEP design
- Leaving departures unlisted, so civil defence finds them at inspection
Questions people ask
Who approves the strategy?
The civil defence authority of the Emirate approves the fire drawings and the strategy behind them, and inspects the installed systems before it issues the completion certificate.
What if the design cannot meet a requirement of the code?
List it as a departure, with the reason and how the same level of safety is reached, for example by fire engineering analysis. Civil defence must accept each one.